Quick Answer
IP68 means the enclosure is dust-tight and protected for continuous immersion beyond 1 meter, with the exact depth and time set by the manufacturer. It is the right choice when the real hazard is prolonged or repeated submersion, not jets or hot washdown.
- Choose IP68 for underwater, flood-prone, or long-immersion environments
- Choose IP66 for powerful water jets and storm-driven spray
- Choose IP69 or IP69K for hot, high-pressure sanitation washdowns
- Always verify the actual immersion depth and duration on the datasheet

IP68 basics (IEC 60529)
IP68 is an ingress protection rating under IEC 60529. The first digit shows protection against solids, and the second shows protection against water under defined test conditions.
- First digit “6” → Dust-tight
- Second digit “8” → Continuous immersion beyond 1 meter, with exact depth and duration set by the manufacturer
The key point is that IP68 does not mean every product survives the same depth or time. Always check the datasheet.
IP68 immersion test

What makes IP68 different from IPX7
The difference is depth and duration. IPX7 covers temporary immersion up to 1 meter for 30 minutes. IP68 goes beyond that, but the exact immersion depth and test time are set by the manufacturer. That is why one IP68 product may be rated for 2 meters while another is rated for much more.
Standard conditions
- The immersion test is normally done in fresh water, not salt water or chemicals
- The test confirms that no harmful amount of water enters under the specified immersion conditions
- Because the rating is manufacturer-defined, the datasheet matters as much as the label
What the test proves
- The enclosure is dust-tight (IP6X).
- It can handle immersion beyond 1 meter for as long as the manufacturer certifies.
- It is suitable for applications like underwater lighting, sensors, junction boxes in pits, or marine terminals.
What the test does not prove
- Not jet-proof. IP68 is about immersion, not water spray or washdowns. For protection against strong jets, you need IP66, and for hot, high-pressure sanitation jets, IP69/IP69K.
- Not corrosion-proof. The IP rating only measures dust and water ingress. It doesn’t cover corrosion or chemical resistance, which depends on the enclosure’s material (stainless steel, coated steel, aluminum, plastic) and finish.
- Not universal. Because each manufacturer sets their own depth/time for IP68, one product rated for 2 m immersion may not perform the same as another rated for 10 m.
IP66 vs IP67 vs IP68 vs IP69/IP69K
| Rating | Dust Protection | Water Protection | Typical Uses |
|---|---|---|---|
| IP66 | Dust-tight | Powerful water jets | Outdoor telecom, rooftops, factory hose-downs |
| IP67 | Dust-tight | Immersion to 1 m for 30 min | Flood-prone sites, underground pits, portable gear |
| IP68 | Dust-tight | Continuous immersion (>1 m; depth/time by maker) | Marine gear, underwater lighting, long-term submersion |
| IP69 / IP69K | Dust-tight | Hot, high-pressure washdowns (not immersion) | Food & beverage, pharma, sanitary washdown zones |
NEMA vs IP: rough mapping + caveats
Both NEMA (used mainly in North America) and IP (IEC 60529) ratings define how well enclosures protect against environmental hazards. While there’s overlap, they are not identical systems—their tests, focus areas, and scope differ.
Typical parallels
- NEMA 6 is often compared with IP67 because both are used for temporary immersion-type applications.
- NEMA 6P is often compared with IP68 because both are used for prolonged immersion-type applications.
Why they’re not strict equivalents
- Different test methods: IP testing focuses only on ingress of dust and water. NEMA testing includes icing, corrosion, oil and coolant exposure, and mechanical damage.
- Corrosion gap: IP68 doesn’t guarantee corrosion resistance, while NEMA 6P explicitly requires it.
- No one-to-one mapping: Saying “IP68 = NEMA 6P” is convenient shorthand, but technically incorrect. They’re functionally similar for immersion, but only NEMA validates against additional stress factors.
Where IP68 shines

IP68 is most useful where the real hazard is repeated or prolonged immersion rather than spray.
- Submersible junctions and pits: Underground electrical vaults, utility pits, and below-grade junction boxes can flood during storms. IP68 helps keep connections protected during prolonged water exposure.
- Flood-prone sites: Pump stations, underpasses, and basement control areas may face repeated immersion. IP68 helps critical equipment survive these conditions.
- Marine and utility installations: Docks, offshore platforms, and coastal substations may face splash, salt spray, and occasional submersion. IP68 is often paired with corrosion-suitable materials, and in some cases NEMA 6P is also considered.
- Underwater lighting and sensors: Pool lights, fountain systems, and marine sensors often operate fully underwater for extended periods. These are classic IP68 applications.
- Critical note: If the site also involves saltwater or chemical exposure, immersion rating alone is not enough. Material choice still matters.
Specifying an IP68 enclosure
An IP68 label is only reliable if the full system—enclosure, accessories, and installation—meets the same requirement. Here’s what to check:

1. Match all accessories to IP68
- Cable glands: Must be IP68-rated and installed with proper torque. One unsealed entry compromises the whole enclosure.
- Breathers & vents: Use IP68-certified versions that equalize pressure without letting water in.
- HMI windows & operator controls: Touchscreens, pushbuttons, and viewing panels need the same IP68 rating, not just the enclosure body.
2. Verify seals and door compression
- Continuous gasket seals: should run unbroken around the door frame.
- Latch pressure: must be even across all sides; a weak point can allow water ingress.
- Material choice: Use gasket compounds rated for immersion and temperature swings (EPDM, silicone).
3. Mounting orientation matters
- As tested: Install the enclosure in the orientation used during its IP68 certification.
- Avoid water traps: Add drip shields or slope tops to help water drain away.
4. Control condensation inside
- Pressure equalization: Use IP68-rated breathers to reduce internal condensation caused by temperature changes.
- Moisture management: Desiccant packs or small heaters can help in humid environments.
5. Confirm test depth and time
- Manufacturer’s datasheet: Always review how deep and how long the enclosure is certified for. Some are rated for 2 m, others for 10 m or more.
- Application match: Make sure the rating aligns with the worst-case immersion scenario for your project.
Decision flow: jets vs. immersion vs. hot wash

Selecting the right IP rating depends on the actual water mode your equipment will face.
Step 1: Is the main hazard powerful spray or storm-driven water?
Yes → Start with IP66
No → Move to Step 2
Step 2: Is the enclosure likely to be submerged?
Yes → Choose an immersion rating
- IP67 for short-term immersion
- IP68 for longer or deeper immersion, with exact depth and time confirmed on the datasheet
No → Move to Step 3
Step 3: Is the site cleaned with hot, high-pressure sanitation jets?
Yes → Move to IP69 or IP69K
No → Stay with the rating that matches the earlier risk
Quick examples
- Rooftop telecom cabinet: IP66
- Flood-prone underground junction box: IP67 or IP68
- Submersible lighting or marine sensor: IP68
- Sanitary control panel in a dairy plant: IP69 or IP69K
Conclusion
IP68 is the right choice when the real hazard is prolonged or repeated immersion. It is not the right choice when the main risk is powerful jets or hot sanitation washdown. The most important detail is not the IP68 label alone, but the actual certified immersion depth and time on the datasheet.
Choose IP68 for immersion. Move to IP66 for jets and IP69 / IP69K for hot, high-pressure washdown.
FAQs About IP68
What does IP68 mean?
IP68 means the enclosure is dust-tight and protected for continuous immersion beyond 1 meter. The exact depth and duration depend on the manufacturer, so the datasheet must always be checked.
Is IP68 waterproof?
IP68 is waterproof for immersion under specified conditions, but it is not a universal answer for every water hazard. It does not automatically mean protection against powerful jets or hot washdown.
What is the difference between IP67 and IP68?
The main difference is immersion depth and duration. IP67 covers temporary immersion, usually up to 1 meter for 30 minutes. IP68 goes beyond that, but the exact limits depend on the manufacturer.
Is IP68 better than IP66?
Not in general. IP68 is better for immersion, while IP66 is better for powerful water jets. The better choice depends on whether the real hazard is submersion or spray.
When should I choose IP68 instead of IP66 or IP67?
Choose IP68 when the enclosure may face deeper or longer immersion than IP67 covers. If the real hazard is only strong spray, IP66 is usually more appropriate.