Quick Answer
IP67 and IP68 are both dust-tight, but they are not the same. IP67 is for brief immersion under standard conditions, while IP68 is for deeper or longer immersion defined by the manufacturer. Choose IP67 for short, shallow submersion risk. Choose IP68 when water may stay deeper or longer around the enclosure, and always verify the exact datasheet limits.
- IP67: Best for brief, shallow immersion
- IP68: Best for deeper or longer immersion
- Both are dust-tight
- Neither one automatically means jet-rated

When you choose an enclosure, the IP rating is the fastest way to judge how well it blocks dust and water. It helps you match protection to real conditions such as rain, splash, jets, or brief submersion.
Pick the right rating and you reduce failures, avoid downtime, and extend equipment life. Pick the wrong one and moisture or grit can get inside, damage components, and lead to costly repairs.
IP Basics (IEC 60529, Two-Digit Code)

IP stands for Ingress Protection. The code uses two digits to show how well an enclosure blocks solids and liquids:
- First digit (0–6) — Solids: Protection against objects and dust. A higher number means tighter sealing. 6 is the maximum and means dust-tight.
- Second digit (0–9) — Liquids: Protection against water, from light drips to spray, jets, and immersion. Again, higher numbers indicate stronger protection.
What IP67 Means
- 6 (solids): Dust-tight — no dust entry.
- 7 (liquids): Protection against temporary immersion, commonly understood as up to 1 m for 30 minutes under standard test conditions.
IP67 is a practical choice for enclosures that may be briefly submerged or sit in pooled water, such as valve boxes, below-grade junctions, or outdoor cabinets in flood-prone areas. It is built for short immersion events, not longer underwater exposure.
What IP68 Means
- 6 (solids): Dust-tight — same top level as IP67.
- 8 (liquids): Protection for immersion beyond 1 m. The exact depth and duration are defined by the manufacturer, and must be checked on the product datasheet.
Use IP68 when equipment may face deeper or longer immersion, such as docks, pits, underground chambers, or sites with recurring flooding. It is built for water that remains around the enclosure, not just brief submersion.
IP67 vs IP68: Key Differences
| Aspect | IP67 | IP68 |
|---|---|---|
| Solids (1st digit) | 6 — Dust-tight | 6 — Dust-tight |
| Liquids (2nd digit) | 7 — Temporary immersion under standard test conditions | 8 — Deeper or longer immersion set by the manufacturer |
| Test intent | Handles brief submersion events | Handles extended or deeper submersion per datasheet |
| Best fit | Pooled water, flood splashes, short-term submersion | Pits, docks, underground chambers, and recurring immersion exposure |
| What it’s not | Not a guarantee for high-pressure jets or long immersion | Not automatically jet-rated and not unlimited-depth waterproof |
| Spec check | Confirm that brief immersion matches site risk | Must check exact depth and duration on the datasheet |
| Cost tendency | Usually lower | Usually higher |
Typical Electrical Enclosure Applications

IP67 — Short, Shallow Immersion Risk
- Below-grade junction boxes where water can pool after storms
- Valve or actuator enclosures in irrigation or wastewater lines that may be briefly submerged
- Outdoor sensor hubs on low plinths or curbs exposed to splash and temporary standing water
- Mobile equipment panels exposed to heavy rain or accidental dunking, but not long immersion
IP68 — Deeper or Longer Immersion
- Dockside and marina cabinets where surge or wake can leave gear underwater for longer
- Underground chambers or pits with recurring high-water events
- Flood-prone infrastructure such as roadside cabinets, culvert controls, or levee monitoring nodes
- Tunnels and basements where sump failures could leave enclosures submerged for extended periods
How to Choose Between IP67 and IP68
Choose between IP67 and IP68 based on real immersion risk, not just on which number looks higher.
- How often will the enclosure be submerged? If submersion is rare, brief, and shallow, IP67 is often enough. If it may happen repeatedly or last longer, IP68 is usually the safer choice.
- How deep can the water get? IP67 is commonly tied to temporary immersion up to 1 meter under standard conditions. If your site can exceed that, move toward IP68.
- How long can the enclosure stay underwater? Short submersion events point toward IP67. Longer retention times point toward IP68.
- Does the IP68 datasheet state exact depth and duration? This is critical. IP68 is not one fixed immersion level. The manufacturer must define the depth and time, so always verify the actual numbers.
- Can installation design reduce the water risk? Raised mounting, drainage improvements, and better enclosure placement can reduce immersion time enough to keep IP67 viable in some projects.
- Are all entry points equally protected? Cable glands, vents, drains, and other penetrations must be rated to the same protection level, or the real installation may fall below the enclosure’s listed IP rating.
Rule of thumb
Choose IP67 for brief, shallow immersion risk.
Choose IP68 for deeper or longer immersion—and verify the exact datasheet limits before specifying it.
Cost & Lifecycle Value

Choosing between IP67 and IP68 is really a total cost of ownership call—balancing upfront price against failures, downtime, and maintenance.
When IP68 Pays Back
- Repeated immersion: Sites with recurring pooling or longer underwater exposure gain from IP68’s deeper or longer immersion tolerance.
- Fewer failures: Better immersion protection can reduce call-outs, component damage, and seal-related repairs after storms or flooding.
- Less downtime: Stronger immersion performance helps keep controls, pumps, and sensors online in water-prone locations.
When IP67 Is the Better Value
- Short, shallow events: If water exposure is rare and brief, IP67 usually protects well at a lower cost.
- Controlled installs: Raised mounting, drip shields, and proper drainage can reduce immersion time enough to make IP67 the smarter choice.
- Better budget use: The savings can go into higher-quality glands, gaskets, latches, or drainage improvements that increase overall reliability.
Testing Notes & Misconceptions

- IP67/68 aren’t jet ratings: They certify immersion (IP67 = temporary; IP68 = deeper/longer per manufacturer), not high-pressure spray. For jets, specify IP66 or IP69K.
- IP covers ingress only: IP ratings tell you how well an enclosure keeps out dust and water—nothing about corrosion, chemicals, UV, or impact.
- Need corrosion resistance? Specify materials/finishes (e.g., 316 stainless steel, powder coat) or choose NEMA 4X for added corrosion testing.
- Concerned about chemicals or sanitation? Confirm gasket compatibility (EPDM/silicone) and cleaner exposure.
- Installations can break the rating: Drilling holes, adding windows, or using the wrong cable glands can downgrade IP67/IP68. Use equally rated glands, vents, and drains, and torque latches evenly to maintain the seal.
- “Higher number = better” isn’t always true: IP67 ≠ IP66 and IP68 ≠ IP69K—they solve different water modes (immersion vs jets). Match the rating to the actual hazard.
Conclusion
IP67 and IP68 both provide dust-tight protection, but they solve different immersion risks. IP67 is the right fit for brief, shallow submersion under standard conditions. IP68 is the better choice when water may stay deeper or longer around the enclosure, but its exact limits must always be confirmed on the datasheet.
Choose IP67 for short immersion events. Choose IP68 for deeper or longer immersion where the risk is real and repeatable.
FAQs About IP67 vs IP68
What is the main difference between IP67 and IP68?
IP67 is for temporary immersion under standard conditions, while IP68 is for deeper or longer immersion defined by the manufacturer. Both are dust-tight, but IP68 always requires a datasheet check.
Is IP68 better than IP67?
Not always. IP68 is better only when the real risk involves deeper or longer immersion. If submersion is brief and shallow, IP67 is often enough and usually more cost-effective.
Are IP67 and IP68 waterproof?
They are immersion-rated, but not in an unlimited sense. IP67 covers brief immersion under standard conditions. IP68 covers deeper or longer immersion, but only within the manufacturer’s stated limits.
Do IP67 and IP68 also mean jet protection?
Not automatically. These ratings are about immersion, not necessarily high-pressure spray. If jet resistance is the real concern, look at ratings such as IP66 or IP69K instead.
Ready to Specify the Right IP Enclosure?

Whether you need IP67 for temporary immersion or IP68 for longer, deeper water exposure, we can help you specify the right enclosure, material, gaskets, and cable-entry hardware for your site conditions. Contact us for application guidance, custom options, and a fast quote.