IP31 Enclosure

ip31 nema 2 carbon steel network server rack COM
IP31 enclosures protect against solid objects larger than 2.5mm and vertically falling water drops, making them ideal for indoor server racks and IT rooms.
ip31 nema 2 carbon steel network server rack COM

Why IP31 Enclosure

Added Water Resistance

Protects equipment from vertically falling water drops, an upgrade over IP30.

Solid Object Protection

Prevents contact with tools or wires larger than 2.5mm, keeping circuits safe.

Optimized for Indoors

Ideal for server racks, telecom rooms, and IT spaces where minor drips or condensation may occur.

Cost-Effective Choice

Provides basic protection without the expense of higher IP-rated waterproof models.

Supports Ventilation

Often designed with airflow features, balancing equipment cooling and safety.

Custom IP31 Enclosures

Applications for IP31 Enclosure

Data Centers and IT Rooms the application of steel enclosure
Data Center
ip30 application indoor telecom enclosure
Telecommunications

How We Control Quality

Our Certificates

All IP Rating Enclosures

More Certificate Enclosures

IP66 rating for electrical enclosure
IP enclosure
NEMA rating for electrical enclosure
NEMA enclosure
ul rating for electrical enclosure
UL enclosure
iecex certificate for electrical enclosure
IECEx box
ip31 rating ingress protection

About IP Rating & IP31

The IP rating (Ingress Protection) system defines how well an enclosure prevents solids and liquids from entering. The first digit rates solid protection, while the second digit measures water resistance.

An IP31 enclosure blocks solid objects larger than 2.5 mm, such as tools and thick wires, and protects against vertically falling water drops. This makes it suitable for indoor server racks, telecom rooms, and office distribution systems where minor drips or condensation may occur.

IP31 vs IP41 vs IP54

Feature IP31 IP41 IP54
Solid Protection Objects ≥ 2.5mm Objects ≥ 1mm Limited dust ingress, no harm
Water Protection Vertical water drips Vertical water drips Water splashes from any direction
Typical Use Server racks, telecom rooms Indoor control panels, clean rooms Workshops, light industrial, semi-damp areas
Relative Cost Low Moderate Higher

IP31 & NEMA Type 2

IP31 & NEMA Type 2

ip31 nema 2 black carbon steel enclosure server rack with side window COM

An IP31 enclosure provides protection against solid objects larger than 2.5 mm and vertically falling water drops. In the NEMA standard, this level of protection is most closely aligned with a NEMA Type 2 enclosure, which also guards against limited dust, accidental contact, and dripping water in indoor environments.

While the two systems are tested differently, using IP31 ≈ NEMA 2 as a reference helps engineers and buyers ensure the right choice for controlled indoor applications such as server racks, utility rooms, and light industrial facilities.

Technician wearing safety gear maintaining and wiring an electrical enclosure to ensure safe operation and reliable performance

Maintenance & Care Tips

Technician wearing safety gear maintaining and wiring an electrical enclosure to ensure safe operation and reliable performance
  1. Inspect Door Seals Regularly – Check gaskets and seals for wear to maintain dust and water protection.
  2. Clean Surfaces & Coatings – Wipe off dust, oil, or salt buildup and keep anti-rust coatings in good condition.

  3. Check Hinges & Locks – Ensure doors close tightly and hardware remains secure for lasting protection.

 

Need IP Rating Enclosure or Custom Rating

FAQs About IP31

What does IP31 mean for an enclosure?

The IP31 rating guards against solid objects larger than 2.5 mm (like tools or wires) and protects against vertically falling water drops (condensation). It’s designed for indoor environments with minor moisture risks.

 

No. An IP31 enclosure offers no waterproof capabilities—it only protects against vertical drips. It’s not suitable for splash protection or wet environments.

 

IP31 enclosures are commonly used in indoor server racks, telecom rooms, IT cabinets, and office environments where dripping condensation may occur and cooling airflow is still important.

 

IP30 only protects against solid objects larger than 2.5 mm and offers no water protection. IP31 adds protection against vertically falling water drops (like condensation), giving it a slight edge in moisture-prone indoor spaces.

 
Yes. IP31 provides tool-sized solid protection and condensation resistance while still allowing airflow—making it ideal for server racks and IT equipment that require cooling in controlled indoor environments.

Insights From Our Industry Leaders

Load center breaker box cover showing residential electrical panel and circuit breakers
Blog
Leo Lu

Load Center: What It Is & How It Works

A load center (breaker box) is the hub of home power: it distributes electricity via breakers, protects circuits, handles main vs sub‑panels, amps & safety.

Electric meter box installation cover showing outdoor meter enclosure wiring safety planning and code compliance steps
Blog
Leo Lu

How to Install an Electric Meter Box

Step-by-step guidance on installing an electric meter box safely—site prep, clearances, mounting height, wiring, grounding, permits, and code compliance explained.

en_USEnglish
logo redpng

Your message will send to E-abel team directly

Leo Lujpg
Leo
Carson Hejpeg
Carson
Paul Caojpeg
Paul
Linsey scaled e1739864096326webp
Linsey
*We respect your confidentiality and all information are protected.
lianjer logo png

Contact us for supplier sourcing, product inquiries, or quotations.

*We respect your confidentiality and all information are protected.
26th pending shanghai offline events long post